Energy
/ Electricity Saving Rate = (C - B) / (C - D) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This Formula has been reviewed and verified by a
third party expert. |
|
|
|
|
|
To
download the original MS. Excel spreadsheet, in your browser, change *.htm to
*.xls |
|
|
|
All temperatures are Calculated in Celsius. |
|
|
Ti = C-D |
|
Ti is the temperature difference between Indoor R/Fs
evaporator & condenser |
|
|
Tw = B-D |
|
Tw is the
temperature difference between Window R/Fs evaporator & condenser |
|
|
B = Outdoor temperature (temperature of window
R/F's condenser). |
|
|
C = Indoor temperature (temperature of indoor R/F's condenser). |
|
|
D = 32 F (0
oCelsius), the assumed fixed temperature of both R/F's
evaporator (fixed). |
|
|
|
|
|
B |
B |
B |
B |
B |
B |
B |
B |
B |
B |
B |
B |
B |
B |
B |
B |
|
|
Fahrenheit |
110 |
105 |
100 |
95 |
90 |
85 |
80 |
75 |
70 |
65 |
60 |
55 |
50 |
45 |
40 |
36 |
|
|
|
Celsius |
43 |
41 |
38 |
35 |
32 |
29 |
27 |
24 |
21 |
18 |
16 |
13 |
10 |
7 |
4 |
2 |
|
C |
110 |
43 |
0% |
6% |
13% |
19% |
26% |
32% |
38% |
45% |
51% |
58% |
64% |
71% |
77% |
83% |
90% |
95% |
|
C |
105 |
41 |
-7% |
0% |
7% |
14% |
21% |
27% |
34% |
41% |
48% |
55% |
62% |
68% |
75% |
82% |
89% |
95% |
|
C |
100 |
38 |
-15% |
-7% |
0% |
7% |
15% |
22% |
29% |
37% |
44% |
51% |
59% |
66% |
74% |
81% |
88% |
94% |
|
C |
95 |
35 |
-24% |
-16% |
-8% |
0% |
8% |
16% |
24% |
32% |
40% |
48% |
56% |
63% |
71% |
79% |
87% |
94% |
|
C |
90 |
32 |
-34% |
-26% |
-17% |
-9% |
0% |
9% |
17% |
26% |
34% |
43% |
52% |
60% |
69% |
78% |
86% |
93% |
|
C |
85 |
29 |
-47% |
-38% |
-28% |
-19% |
-9% |
0% |
9% |
19% |
28% |
38% |
47% |
57% |
66% |
75% |
85% |
92% |
|
C |
80 |
27 |
-63% |
-52% |
-42% |
-31% |
-21% |
-10% |
0% |
10% |
21% |
31% |
42% |
52% |
63% |
73% |
83% |
92% |
|
C |
75 |
24 |
-81% |
-70% |
-58% |
-47% |
-35% |
-23% |
-12% |
0% |
12% |
23% |
35% |
47% |
58% |
70% |
81% |
91% |
|
C |
70 |
21 |
-105% |
-92% |
-79% |
-66% |
-53% |
-39% |
-26% |
-13% |
0% |
13% |
26% |
39% |
53% |
66% |
79% |
89% |
|
C |
65 |
18 |
-136% |
-121% |
-106% |
-91% |
-76% |
-61% |
-45% |
-30% |
-15% |
0% |
15% |
30% |
45% |
61% |
76% |
88% |
|
C |
60 |
16 |
-179% |
-161% |
-143% |
-125% |
-107% |
-89% |
-71% |
-54% |
-36% |
-18% |
0% |
18% |
36% |
54% |
71% |
86% |
|
C |
55 |
13 |
-239% |
-217% |
-196% |
-174% |
-152% |
-130% |
-109% |
-87% |
-65% |
-43% |
-22% |
0% |
22% |
43% |
65% |
83% |
|
C |
50 |
10 |
-333% |
-306% |
-278% |
-250% |
-222% |
-194% |
-167% |
-139% |
-111% |
-83% |
-56% |
-28% |
0% |
28% |
56% |
78% |
|
|
|
|
|
|
|
Note: Under 0% area is when outdoors is warmer than indoors (A/C is On). |
|
|
|
When A/C is On, there is no Net energy savings. See bottom of page. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|